IES & LDT Photometric Files for Lighting Designers | DIALux Ready | YNDLUX

Source de l'article:null

Date de publication:2026-07-12 21:25:57

Nombre de vues:2093

Professional lighting design requires accurate photometric data. YNDLUX provides complete technical support for lighting designers and specifiers — IES files, LDT (EULUMDAT) files, spectral data, and DIALux/Relux-ready product libraries for every luminaire we manufacture. Direct from the factory that controls optical design, testing, and production.

Photometric Files Available

LDT (EULUMDAT) Files

The standard photometric format across Europe and much of Asia. Contains:

  • Luminous intensity distribution (candela values at all angles)
  • Luminaire efficiency and light output ratio
  • Beam angle data (half-peak intensity)
  • Physical dimensions for accurate 3D placement

YNDLUX provides LDT files measured on our in-house goniophotometer for every product variant.

IES Files

Standard format for North American markets (IESNA LM-63). Same photometric data in IES format for use in AGi32, Visual, and other North American design software.

Spectral Power Distribution (SPD)

Available on request for color-critical applications (museums, galleries, retail, healthcare).

Design Software Compatibility

YNDLUX photometric files are tested and verified in:

  • DIALux evo — Import LDT directly into the luminaire database
  • Relux — Full product data including LDT and product images
  • AGi32 — IES import for calculation and visualization
  • Visual by Acuity — IES format

What We Test In-House

YNDLUX operates a photometric laboratory with:

  • Goniophotometer (Type C) — Measures luminous intensity distribution, calculates lm/W efficiency, beam angle, and generates IES/LDT files
  • Integrating sphere (1.5m) — Measures total luminous flux, CCT accuracy, CRI/Ra/R9, and color consistency (MacAdam ellipses)
  • Spectroradiometer — Full SPD measurement for color rendering analysis

All photometric data is measured on production samples (not theoretical calculations).

Technical Documentation Package

For every YNDLUX product, specifiers receive:

  • ✓ LDT file (goniophotometer-measured)
  • ✓ IES file
  • ✓ Technical datasheet (PDF)
  • ✓ Installation guide
  • ✓ DXF/STEP 3D drawings (on request)
  • ✓ CE/ENEC/CB certificates

Free Lighting Calculation Service

Send us your project floor plan and requirements. Our in-house lighting designers will provide:

  • DIALux/Relux simulation with compliance verification (EN 12464-1, etc.)
  • Product specification and bill of quantities
  • Energy calculation (installed watts/m², annual kWh)
  • UGR verification at observer positions

No cost, no obligation. This service is available to specifiers, designers, and contractors worldwide.

Request Photometric Files

Need IES/LDT files for a specific YNDLUX product? Contact our technical team:

Contactez-nous

Soumettre

Yndlux Lighting Co.,Ltd

Adresse:Yihui 3rd Road, Maohui Industrial Zone, Henglan Town, Zhongshan, GuangDong, China.

Code postal:528400

Téléphone:+86 0760-8756 6998

Téléphone Mobile:+86 135 9073 9663,+86 189 2536 8811

Boîte mail:info@yndled.com

email

公司备份